When insulating hvac ductwork use a foil faced fiberglass insulation with an r 6 or higher r value.
Insulating hvac ducts in attic.
But our erv ducts stand alone system not tied in w heat pump and 2 jumper ducts for pressure balancing from bedrooms are suspended above the insulation in our vented attic.
Unfortunately so many houses especially newer homes end up with ductwork running through the attic.
Purchase duct wrap insulation that complies with the 2009 international energy conservation code iecc standards that specify an r value of 8 for attic ducts and 6 for ducts located anywhere else.
Our heating and ac ducts are 100 within the thermal envelope in the floor trusses above our insulated basement.
She asked me to go into the attic to find the roof leaks or where the snow is blowing in through the soffits.
First water dripping off of your ducts and onto your insulation can cause the insulation to compress which decreases it s r value or ability to insulate.
Install ductwork so that it is in direct contact with i e laying on the ceiling and or truss lower cords.
Apply a long strip of foil tape along the seam in the insulation.
Why is condensation on ductwork a problem.
Why is this a problem.
Use the type of metallic foil duct tape recommended by the insulation manufacturer to seal and hold the insulation in place.
Duct insulation keeps air that s supposed to be cool cool and air that s supposed to be warm warm.
Secure the insulation with short strips of foil tape.
The greater the temperature extreme between the air inside the duct and the air surrounding the ductwork the greater your need for duct insulation.
Insulated ducts have been the standard for decades now.
The rigid insulation was saturated from condensation.
This of course is a good thing.
Wrap the insulation around the duct and then pinch the seam closed.
I found instead a vintage 3 ton ac unit with 1 rigid insulation taped all over it and insulated flex duct snaking all over the poorly insulated attic.
Repeat to insulate the remaining ducts.
Close to 25 of the energy you use to heat and cool your home disappears through leaky ductwork.
To install preformed duct insulation start by disconnecting an elbow to expose the end of the duct.
When water condenses and drips into your attic or home it can cause a some serious secondary problems.
The department of energy claims that the average us home loses hundreds of dollars a year in heating and cooling costs.
No building inspector worth his or her salt is going to let any builder or hvac contractor get away with installing ducts that aren t insulated.
Use metal flex or fiber board ducts that are insulated to.